FA730 540.00 EuroFA730 Field Analyzer
The low frequency fields are also audible on the speaker, and their waveform is visible on the screen. The delivery includes a LogPer antenna (for 700 to 6000 MHz) and batteries (see manual). Manual FA720-735 version 1.5 Manuel FA720-735 V1.5 Brugervejledning FA735 V1.2 Handleiding FA720-735 version 1.5 FA730 Field AnalyzerFA730 540.00 EuroHigh frequency: Frequency range: 300-6000 MHz Measurement range: 0.05-2000 ?W/m? Number of measurement ranges: 3 Auto range switch: Yes Display units: ?W/m?, mV/m, dBm Frequency measurement: Yes Functions: peak, peak-hold, pulse-shape Speaker: signal sound Output: signal-AC Logper antenna: Yes Low frequency electric field: Frequency range: 15-300 Hz Measurement range: 0.5-199 V/m Accuracy: 10 % Acoustic function: Yes Low frequency magnetic field: Frequency range: 40-7000 Hz Measurement range: 10-3990 nT Accuracy: 10 % Acoustic function: Yes General: Display: graphic, adjustable backlight Power supply: 2 AA battery, Accu pack(Option), Charger(Option) Manual languages: English, Fran?ais, Dansk, Nederlands
The low frequency fields are also audible on the speaker, and their waveform is visible on the screen. The delivery includes a LogPer antenna (for 700 to 6000 MHz) and batteries (see manual). Manual FA720-735 version 1.5 Manuel FA720-735 V1.5 Brugervejledning FA735 V1.2 Handleiding FA720-735 version 1.5 FA735 640.00 EuroFA735 Field Analyzer
This device has a big RF frequency range of 300 MHz up to 6 GHz (when a suitable antenna is used). For the RF field, not only the strength, but also its frequency can be measured (see manual). This model can also measure low frequency (electric and magnetic) fields. The low frequency fields are also audible on the speaker, and their waveform is visible on the screen. It also contains a datalogger function. The data logging function writes the measurement results to a micro-SD memory card every 10 seconds. It writes the current time and date together with these measurements. The recorded data can be viewed on the device itself, or on your PC (as an Excel spreadsheet). The delivery includes a LogPer antenna (for 700 to 6000 MHz) and batteries (see manual). For the datalogging, the memory card and a card reader (to connect the memory card to the PC) are included. The FA735 is delivered in a protective carrying case. Manual FA720-735 version 1.5 Manuel FA720-735 V1.5 Brugervejledning FA735 V1.2 Handleiding FA720-735 version 1.5 FA735 Field AnalyzerFA735 640.00 EuroHigh frequency: Frequency range: 300-6000 MHz Measurement range: 0.05-2000 ?W/m? Number of measurement ranges: 3 Auto range switch: Yes Display units: ?W/m?, mV/m, dBm Frequency measurement: Yes Functions: peak, peak-hold, pulse-shape Speaker: signal sound Output: signal-AC Logper antenna: Yes Low frequency electric field: Frequency range: 15-300 Hz Measurement range: 0.5-199 V/m Accuracy: 10 % Acoustic function: Yes Low frequency magnetic field: Frequency range: 40-7000 Hz Measurement range: 10-3990 nT Accuracy: 10 % Acoustic function: Yes General: Datalogger: Yes Display: graphic, adjustable backlight Power supply: 2 AA battery, Accu pack(Option), Charger(Option) Manual languages: English, Fran?ais, Dansk, Nederlands
This device has a big RF frequency range of 300 MHz up to 6 GHz (when a suitable antenna is used). For the RF field, not only the strength, but also its frequency can be measured (see manual). This model can also measure low frequency (electric and magnetic) fields. The low frequency fields are also audible on the speaker, and their waveform is visible on the screen. It also contains a datalogger function. The data logging function writes the measurement results to a micro-SD memory card every 10 seconds. It writes the current time and date together with these measurements. The recorded data can be viewed on the device itself, or on your PC (as an Excel spreadsheet). The delivery includes a LogPer antenna (for 700 to 6000 MHz) and batteries (see manual). For the datalogging, the memory card and a card reader (to connect the memory card to the PC) are included. The FA735 is delivered in a protective carrying case. Manual FA720-735 version 1.5 Manuel FA720-735 V1.5 Brugervejledning FA735 V1.2 Handleiding FA720-735 version 1.5 FA845 920.00 EuroFA845 Field Analyzer
The spectrum analyzer is slower than wideband, however, because it has to scan the frequency range, and in one second it can for instance measure 100 different frequencies (while the wideband mode measures all frequencies at the same time). With the new software version V2.3, the spectrum analyzer can also measure pulsed signals. The frequency range and bandwidth can be selected, and pre-set settings are available for the frequency bands of interest. You can also program your own settings. The results of the scans are logged on the memory card. The FA845 looks the same as the FA735. The delivery includes a LogPer antenna (for 700 to 6000 Mhz), protective carrying case, batteries, memory card and a card reader. Manual FA845 version 1.5 Manuel d'utilisateur FA845 V1.5 Brugervejledning FA845 V1.2 Handleiding FA845 versie 1.5 FA845 Field AnalyzerFA845 920.00 EuroHigh frequency: Frequency range: 300-6000 MHz Measurement range: 0.05-2000 ?W/m? Number of measurement ranges: 3 Auto range switch: Yes Display units: ?W/m?, mV/m, dBm Frequency measurement: Yes Functions: peak, peak-hold, pulse-shape Speaker: signal sound Output: signal-AC Logper antenna: Yes Spectrum analyzer: Frequency range: 10-3700 MHz Measurement range: 0.0001-2000 ?W/m? Low frequency electric field: Frequency range: 15-300 Hz Measurement range: 0.5-199 V/m Accuracy: 10 % Acoustic function: Yes Low frequency magnetic field: Frequency range: 40-7000 Hz Measurement range: 10-3990 nT Accuracy: 10 % Acoustic function: Yes General: Datalogger: Yes Display: graphic, adjustable backlight Power supply: 2 AA battery, Accu pack(Option), Charger(Option) Manual languages: English, Fran?ais, Dansk, Nederlands
The spectrum analyzer is slower than wideband, however, because it has to scan the frequency range, and in one second it can for instance measure 100 different frequencies (while the wideband mode measures all frequencies at the same time). With the new software version V2.3, the spectrum analyzer can also measure pulsed signals. The frequency range and bandwidth can be selected, and pre-set settings are available for the frequency bands of interest. You can also program your own settings. The results of the scans are logged on the memory card. The FA845 looks the same as the FA735. The delivery includes a LogPer antenna (for 700 to 6000 Mhz), protective carrying case, batteries, memory card and a card reader. Manual FA845 version 1.5 Manuel d'utilisateur FA845 V1.5 Brugervejledning FA845 V1.2 Handleiding FA845 versie 1.5 AL700 70.00 EuroAL700 Log-per antennaThis antenna has a remarkable frequency range from 700 MHz up to 6 GHz. It is direction sensitive, so it will give you the possibility to decide from which direction a signal comes.In the spring of 2017, the European commission has recommended the 700-800 MHz range to be used for 5G (Fifth generation mobile). This made us decide to design an antenna that includes this 700-800 MHz range. This antenna is included in the delivery of all F720, FA725, FA730, FA735 and FA845 devices. AL700 Log-per antennaAL700 70.00 EuroIn the spring of 2017, the European commission has recommended the 700-800 MHz range to be used for 5G (Fifth generation mobile). This made us decide to design an antenna that includes this 700-800 MHz range. This antenna is included in the delivery of all F720, FA725, FA730, FA735 and FA845 devices. FA-CASE 40.00 EuroFA-CASE Carrying caseThe carrying case is perfect for storage or transportation of your instrument. Your device is protected by the foam interior. The foam has laser-cut openings that are a perfect fit for your instrument and its accessories.This case is included in the delivery of FA735 and FA845 devices. FA-CASE Carrying caseFA-CASE 40.00 EuroThis case is included in the delivery of FA735 and FA845 devices. FA-CH-EU 25.00 EuroFA-CH-UK 30.00 EuroFA-CH-US 30.00 EuroFA-CH-AU 30.00 EuroFA-CH rechargeable battery set and chargerA pair of high-quality NiMH rechargeable batteries and a suitable charging device (that connects to your instrument). The batteries can stay in the instrument during charging. Available for several countries.
Suitable for all F720, FA725, FA730, FA735 and FA845 devices. FA-CH rechargeable battery set and chargerFA-CH-EU 25.00 EuroFA-CH-UK 30.00 EuroFA-CH-US 30.00 EuroFA-CH-AU 30.00 Euro
Suitable for all F720, FA725, FA730, FA735 and FA845 devices. ANT-800 25.00 EuroANT-2400 25.00 EuroANT-400 25.00 EuroOmni-directional antennasOmni-directional antennas are available for several frequency bands. They can be used for long-term measurements when it is not clear from which direction a signal will come. The measured level with the ANT-800 and ANT-2400 antennas will be lower than measured with the AL700 antenna. The antenna is normally used in vertical direction.The GSM antenna covers all GSM bands, and UMTS. The WLAN antenna covers both the 2.4 GHz and 5 GHz bands.
These antennas have an SMA connector and are suitable for all F720, FA725, FA730, FA735 and FA845 devices. Omni-directional antennasANT-800 25.00 EuroANT-2400 25.00 EuroANT-400 25.00 EuroThe GSM antenna covers all GSM bands, and UMTS. The WLAN antenna covers both the 2.4 GHz and 5 GHz bands.
These antennas have an SMA connector and are suitable for all F720, FA725, FA730, FA735 and FA845 devices. ME3030B 179.00 EuroME3030B Digital electrosmog analyserallows an uncomplicated evaluation of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness.The measured values are reliably displayed directly in the entity corresponding to the building biology standard values, namely
An acoustic signal proportional to the field strength with “Geiger-counter-effect” helps identifying regions with increased exposure. Simple operation with the help of a detailed instruction and measurement manual. Scope of supply: Measurement device, grounding cable, Alkaline Mangan battery, detailed instruction manual with factual background information ME3030B Anleitung ME3030B Instruction manual ME3030B Digital electrosmog analyserME3030B 179.00 EuroLow frequency electric field: Frequency range: 16-2000 Hz Measurement range: 1-2000 V/m Accuracy: 2 % Signal strength as sound pitch: Yes Low frequency magnetic field: Frequency range: 16-2000 Hz Measurement range: 1-2000 nT Accuracy: 2 % Signal strength as sound pitch: Yes General: Display: 3.5 digit Power supply: 9V battery Manual languages: Deutsch, English The measured values are reliably displayed directly in the entity corresponding to the building biology standard values, namely
An acoustic signal proportional to the field strength with “Geiger-counter-effect” helps identifying regions with increased exposure. Simple operation with the help of a detailed instruction and measurement manual. Scope of supply: Measurement device, grounding cable, Alkaline Mangan battery, detailed instruction manual with factual background information ME3030B Anleitung ME3030B Instruction manual ME3830B 249.00 EuroME3830B Digital electrosmog analyserHas the same features and configuration as the ME3030B, however additionally offers a clearly extended frequency range: from 5 Hertz to 100 Kilohertz. This frequency range (in accordance with SBM) also includes the higher frequencies caused by, for instance, energy saving lamps, switching-mode power supplies, electronic dimmers, or monitors, which are considered especially critical.ME3830B Anleitung ME3830B Instruction manual ME3830B Digital electrosmog analyserME3830B 249.00 EuroLow frequency electric field: Frequency range: 5-100000 Hz Measurement range: 1-2000 V/m Accuracy: 2 % Signal strength as sound pitch: Yes Low frequency magnetic field: Frequency range: 5-100000 Hz Measurement range: 1-2000 nT Accuracy: 2 % Signal strength as sound pitch: Yes General: Display: 3.5 digit Power supply: 9V battery Manual languages: Deutsch, English ME3830B Anleitung ME3830B Instruction manual ME3840B 299.00 EuroME3840B Digital electrosmog analyserHas the same frequency response, features, and configuration as the ME3830B, however additionally offers a switchable, internal filter module like in the professional devices, allowing a numeric differentiation of traction power and mains supply as well as the artificial higher frequencies. A useful aspect considering the differing precautionary values for lower and for higher frequencies.ME3840B Anleitung ME3840B Instruction manual ME3840B Digital electrosmog analyserME3840B 299.00 EuroLow frequency electric field: Frequency range: 5-100000 Hz Measurement range: 1-2000 V/m Frequency filter function: Yes Accuracy: 2 % Signal strength as sound pitch: Yes Low frequency magnetic field: Frequency range: 5-100000 Hz Measurement range: 1-2000 nT Frequency filter function: Yes Accuracy: 2 % Signal strength as sound pitch: Yes General: Display: 3.5 digit Power supply: 9V battery Manual languages: Deutsch, English ME3840B Anleitung ME3840B Instruction manual ME3851A 399.00 EuroME3851A Digital electrosmog analyserThis device represents the low cost access to the professional, quantitative low frequency measurement technology. It is suitable for measurement certificates, comprises all features of the ME3840B, however additionally offers:
Scope of supply: Measurement device, highly flexible grounding cable with a copper diameter of 1mm², grounding clamp, NiMH battery inside the meter, mains adaptor, battery charger, various adaptors, detailed instruction manual ME3851A Anleitung ME3851A Instruction manual ME3851A Digital electrosmog analyserME3851A 399.00 EuroLow frequency electric field: Frequency range: 5-100000 Hz Measurement range: 1-2000 V/m Frequency filter function: Yes Accuracy: 2 % Signal strength as sound pitch: Yes Output: signal-AC Low frequency magnetic field: Frequency range: 5-100000 Hz Measurement range: 1-2000 nT Frequency filter function: Yes Accuracy: 2 % Signal strength as sound pitch: Yes Output: signal-AC General: Display: 3.5 digit Power supply: Accu pack, Charger Manual languages: Deutsch, English
Scope of supply: Measurement device, highly flexible grounding cable with a copper diameter of 1mm², grounding clamp, NiMH battery inside the meter, mains adaptor, battery charger, various adaptors, detailed instruction manual ME3851A Anleitung ME3851A Instruction manual
|